GD-9168A Digital Vacuum Distillation Tester Common Fault And Solutions

Views: 12     Author: Site Editor     Publish Time: 2024-01-16      Origin: Site

Inquire

facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Maintenance:

1. Keep the instrument clean.  Prevent the erosion of acid, alkali, oil and moisture. Especially the electronic control part, make sure that water cannot enter and do not make it damp.

2. Frequently check whether the instrument is well grounded to ensure the safety of the operator.

3. Before the first use of the vacuum bump, check and ensure that the vacuum pump oil in the pump reaches the window scale line.

4. When the instrument is out of order, please ask professional personnel to repair or contact our company in time. Do not disassemble or remove.

5. During the test, do not touch the heating part of the instrument. Be careful and do not splash oil and other liquids on the instrument to ensure the safe use of the instrument.

6. Before the working of the instrument, the nitrogen outlet pressure should be adjusted no more than 30kPa, and then connect the nitrogen pipeline for standby.  Open the nitrogen valve when need (you will hear the sound of gas letting out), when the system finishes the pressure releasing, close the nitrogen valve accordingly.



Common fault and solutions:

Common faults

Causes

Solutions

Power indicator not on after power on

1.Power supply is not connected.

2. Power fuse has blown.

1. Check the power supply is properly connected, if the power socket is loose or not. If so, solve it accordingly.

2. Check and replace the fuse.

Power indicator on, but the screen not on


IPC power supply circuit is not connected or fall off.

Check if IPC power supply circuit is not connected or fall off.  If so, solve it accordingly.

Furnace not heating

1. The power of the furnace is not connected properly.

2. The fuse of the furnace has blown.

1. Check the power of the furnace is properly connected, the power socket is loose or not.  If so, solve it accordingly.

2. Check the fuse has blown or not.  If so, solve it accordingly.

Error between thermometers temperature and instrument screens display temperature


1. Temperature sensor is not properly inserted in the correct position

2. Plugs and socket of the temperature sensor is loose

1. Check the position of the temperature sensor is right or not.  Correct it accordingly.

2. Check the plug and socket is loose or not, if so, re-put it.

Vacuum degree cannot reach the set value


1. The sealing of each glass grinding mouth is not good..

2.There is obvious air leakage point at the joint of the vacuum pipe

1. Reapply the sealing greased to the vacuum plug and the glass grinding mouth.

2. Check each joint of the vacuum pipe to remove the air leakage point.

Unable to reach the set vacuum equilibrium point, vacuum pump frequently started

1. There’s a slight air leakage at the sealing of the glass grinding mouth.

2. There’s slight air leakage at the joint of the vacuum pipe.

1. Check out the air leakage point and reapply the sealing greased.

2. Check out the air leakage point and solve accordingly.



Full set of Petroleum Product Vacuum Distillation Tester:

No.

Description

Qty.

Remark

1

Instrument subject

1


2

Vacuum bump(2L)

1

Installed in the instrument

3

Heat resistant distillation flask

2


4

Vacuum jacket distillation column assembly and receiver

1

On the instrument

5

Clamp of the grinding mouth

3

On the instrument

6

Drop chain

1


7

Funnel

1

For water adding use

8

Silicone tube(φ8×φ6mm,1m)

1

For overflow pipe and drain valve use

9

PU tube(φ6×φ4mm,4m)

1

For connecting nitrogen cylinders use

10

Vacuum sealing grease

1

For glass grinding mouth sealing use

11

Pressure correction fittings(include inrubber plug and Ф6PU tube)

1

For pressure correction use

12

Flask insulated jacket

1


13

Zeolite(porcelain tube)

1

For test use

14

Grinding adapter (glass)

1


15

Aurilave

1

For draining the water use

Automatic Vacuum Distillation ApparatusASTM D1160 Vacuum Distillation Apparatus broadsideVacuum Distillation Apparatus broadside

Gold Mechanical & Electrical Equipment

We're here to offer you professional, fast, comprehensive and high-quality services.
Our marketing network covers all countries worldwide and thus can provide high-quality pre-sale, in-sale and after-sale services for customers as soon as possible. 

Products

Quick Links

​Copyright © Chongqing Gold Mechanical&Electrical Equipment Co.,Ltd.  All Rights Reserved. Site Map  Supported by Leadong.com